Skip to main navigation Skip to search Skip to main content

Bovine and feline Tritrichomonas foetus total cellular protein mass spectrometry data files

Dataset

Description

This is the raw data from Mass Spectrometry analysis of spots resolved using two-dimensional analysis from a total protein sample from Tritrichomonas foetus bovine and feline genotypes. The dataset contains data files generated following the analysis of protein spots using LC-MS/MS.

There are two types of data files.

.Wiff files were produced using the following procedure: \n\nLC−MS/MS was performed using a QSTAR Elite hybrid Q-TOF mass spectrometer (Applied Biosystems, Sciex, USA). The peptides were washed off the trap at 300 nL min-1 onto a PicoFrit column (75 μm × 100 mm) (New Objective, USA) packed with Magic C18AQ resin (Michrom Bioresources, USA), and the following protocol was used to elute peptides from the column and into the source of a QSTAR Elite hybrid Q-TOF mass spectrometer (Applied Biosystems, Sciex, USA): 5−30% MS buffer B (98% acetonitrile−0.2% formic acid) over 8 minutes, 30−80% MS buffer B over 3 minutes, 80% MS buffer B for 2 minutes, 80−85% MS buffer B for 3 minutes. MS/MS fragmentation ion scans were calibrated using fragments of Glu-Fibrinopeptide B. MS/MS spectral data was converted to Mascot Generic format using TOF/TOF extractor V2.1 (Michigan Proteome Consortium, 2003).

.raw files were produced using the following procedure:\n\nLC-MS/MS analysis was undertaken using a nanoAcquity UPLC (Waters, USA) coupled to a XevoQToF (Waters, USA) mass spectrometer. The peptides were washed off the trap at 400 nL/min on to a C18 BEH analytical column (75 μm ´ 100 mm)(Waters, USA), packed with 1.7 μm particles of pore size 130 Å and the following protocol was used to elute peptides from the column into the source of a XevoQToF mass spectrometer (Waters, USA): 1-50% MS buffer B (98% acetonitrile, 0.2% formic acid) over 30 minutes, 50-85% MS Buffer B over 2 minutes, 85% MS buffer B 3 minutes, 85-99% over 1 minute. After separation, the peptides were analysed using tandem mass spectrometry, implementing an emitter tip that tapers to 10 µm at 2300 V. A Data Directed Acquisition (DDA) experiment was performed which continuously scanned for peptides of charge state 2+ to 4+ with an intensity of more than 50 counts per second, with a maximum of three ions in any given 3 second scan.

The data can be accessed via the related website listed below.
Date made available1 Jan 2016
PublisherWestern Sydney University
Date of data production7 Mar 2014 - 20 Mar 2014

Cite this