TY - JOUR
T1 - A molecular machine biosensor : construction, predictive models and experimental studies
AU - Moradi-Monfared, Sahar
AU - Krishnamurthy, Vikram
AU - Cornell, Bruce
PY - 2012
Y1 - 2012
N2 - This paper describes the construction, operation and predictive modeling of a molecular machine, functioning as a high sensitivity biosensor. Embedded gramicidin A (gA) ionchannels in a self-assembled tethered lipid bilayer act as biological switches in response to target molecules and provide a signal amplification mechanism that results in high sensitivity molecular detection. The biosensor can be used as a rapid and sensitive point of care diagnostic device in different media such as human serum, plasma and whole blood without the need for pre and post processing steps required in an enzyme-linked immunosorbent assay. The electrical reader of the device provides the added advantage of objective measurement. Novel ideas in the construction of the molecular machine, including fabrication of biochip arrays, and experimental studies of its ability to detect analyte molecules over a wide range of concentrations are presented. Remarkably, despite the complexity of the device, it is shown that the response can be predicted by modeling the analyte fluid flow and surface chemical reactions. The derived predictive models for the sensing dynamics also facilitate determining important variables in the design of a molecular machine such as the ion channel lifetime and diffusion dynamics within the bilayer lipid membrane as well as the bio-molecular interaction rate constants.
AB - This paper describes the construction, operation and predictive modeling of a molecular machine, functioning as a high sensitivity biosensor. Embedded gramicidin A (gA) ionchannels in a self-assembled tethered lipid bilayer act as biological switches in response to target molecules and provide a signal amplification mechanism that results in high sensitivity molecular detection. The biosensor can be used as a rapid and sensitive point of care diagnostic device in different media such as human serum, plasma and whole blood without the need for pre and post processing steps required in an enzyme-linked immunosorbent assay. The electrical reader of the device provides the added advantage of objective measurement. Novel ideas in the construction of the molecular machine, including fabrication of biochip arrays, and experimental studies of its ability to detect analyte molecules over a wide range of concentrations are presented. Remarkably, despite the complexity of the device, it is shown that the response can be predicted by modeling the analyte fluid flow and surface chemical reactions. The derived predictive models for the sensing dynamics also facilitate determining important variables in the design of a molecular machine such as the ion channel lifetime and diffusion dynamics within the bilayer lipid membrane as well as the bio-molecular interaction rate constants.
KW - bilayer lipid membranes
KW - biosensors
KW - ion channels
UR - http://handle.uws.edu.au:8081/1959.7/uws:30920
U2 - 10.1016/j.bios.2012.02.018
DO - 10.1016/j.bios.2012.02.018
M3 - Article
SN - 0956-5663
VL - 34
SP - 261
EP - 266
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 1
ER -