Adenosine triphosphate (ATP) sampling algorithm for monitoring the cleanliness of surgical instruments

D.O. Pontes, D. D. M. Costa, P. P. D. S. Pereira, Greg S. Whiteley, T. Glasbey, A. F. V. Tipple

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background Timely detection of cleaning failure is critical for quality assurance within Sterilising Service Units (SSUs). Rapid Adenosine Triphosphate (ATP) testing provides a real time and quantitative indication of cellular contaminants, when used to measure surface or device cleanliness. The aim of this study was to investigate the use of an ATP algorithm and to whether it could be used as a routine quality assurance step, to monitor surgical instruments cleanliness in SSUs prior to sterilisation. Methods Cleanliness monitoring using rapid ATP testing was undertaken in the SSUs of four hospitals located in the western (Amazonia) region of Brazil. ATP testing was conducted (Clean Trace, 3M) on 163 surgical instruments, following manual cleaning. A sampling algorithm using a duplicate swab approach was applied to indicate surgical instruments as (i) very clean, (ii) clean, (iii) equivocal or (iv) fail, based around a ‘clean’ cut-off of 250 Relative Light Units (RLU) and a ‘very clean’ <100 RLU. Results The four cleanliness categories were significantly differentiated (P≤0.001). The worst performing locations (hospitals A & C) had failure rates of 39.2% and 32.4%, respectively, and were distinctly different from hospitals B & D (P≤0.001). The best performing hospitals (B & D) had failure rates of 7.7% and 2.8%, respectively. Conclusion The ATP testing algorithm provides a simple to use method within SSUs. The measurements are in real time, quantitative and useful for risk-based quality assurance monitoring, and the tool can be used for staff training. The four-tiered approach to the grading of surgical instrument cleanliness provides a nuanced approach for continuous quality improvement within SSU than does a simple pass/fail methodology.

Original languageEnglish
Article numbere0284967
Number of pages11
JournalPLoS One
Volume18
Issue number8 August
DOIs
Publication statusPublished - Aug 2023

Bibliographical note

Publisher Copyright:
Copyright: © 2023 Pontes et al.

Open Access - Access Right Statement

© 2023 Pontes et al. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Fingerprint

Dive into the research topics of 'Adenosine triphosphate (ATP) sampling algorithm for monitoring the cleanliness of surgical instruments'. Together they form a unique fingerprint.

Cite this