TY - JOUR
T1 - Alfentanil versus fentanyl for emergency department rapid sequence induction with ketamine
T2 - a-FAKT, a pilot randomized trial
AU - Zhang, Yichen
AU - Miller, Matthew
AU - Buttfield, Alexander
AU - Burns, Brian
AU - Lawrie, Kimberley
AU - Gaston, James
AU - Ferguson, Ian
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/10
Y1 - 2024/10
N2 - Background: Fentanyl is often administered during rapid sequence induction of anesthesia (RSI) in the emergency department (ED) to ameliorate the hypertensive response that may occur. Due to its more rapid onset, the use of alfentanil may be more consistent with both the onset time of the sedative and the commencement of laryngoscopy. As such, we compared the effect of alfentanil and fentanyl on post-induction hemodynamic changes when administered as part of a standardized induction regimen including ketamine and rocuronium in ED RSI. Methods: This was a double-blind pilot randomized controlled trial of adult patients requiring RSI in the ED of three urban Australian hospitals. Patients were randomized to receive either alfentanil or fentanyl in addition to ketamine and rocuronium for RSI. Non-invasive blood pressure and heart rate were measured immediately before and at two, four, and six minutes after induction. The primary outcome was the occurrence of at least one post-induction systolic blood pressure outside the pre-specified range of 100-160mmHg (with adjustment for patients with baseline hypertension). Secondary outcomes included hypertension, hypotension, hypoxia, first-pass intubation success, 30-day mortality, and the pattern of hemodynamic changes. Results: A total of 61 patients were included in the final analysis (31 in the alfentanil group and 30 in the fentanyl group). The primary outcome was met in 58% of the alfentanil group and 50% of the fentanyl group (difference 8%, 95% confidence interval: -17% to 33%). The 30-day mortality rate, first-pass success rate, and incidences of hypertension, hypotension, and hypoxia were similar between the groups. There were no significant differences in systolic blood pressure or heart rate between the groups at any of the measured time-points. Conclusion: Alfentanil and fentanyl produced comparable post-induction hemodynamic changes when used as adjuncts to ketamine in ED RSI. Future studies could consider comparing different dosages of these opioids.
AB - Background: Fentanyl is often administered during rapid sequence induction of anesthesia (RSI) in the emergency department (ED) to ameliorate the hypertensive response that may occur. Due to its more rapid onset, the use of alfentanil may be more consistent with both the onset time of the sedative and the commencement of laryngoscopy. As such, we compared the effect of alfentanil and fentanyl on post-induction hemodynamic changes when administered as part of a standardized induction regimen including ketamine and rocuronium in ED RSI. Methods: This was a double-blind pilot randomized controlled trial of adult patients requiring RSI in the ED of three urban Australian hospitals. Patients were randomized to receive either alfentanil or fentanyl in addition to ketamine and rocuronium for RSI. Non-invasive blood pressure and heart rate were measured immediately before and at two, four, and six minutes after induction. The primary outcome was the occurrence of at least one post-induction systolic blood pressure outside the pre-specified range of 100-160mmHg (with adjustment for patients with baseline hypertension). Secondary outcomes included hypertension, hypotension, hypoxia, first-pass intubation success, 30-day mortality, and the pattern of hemodynamic changes. Results: A total of 61 patients were included in the final analysis (31 in the alfentanil group and 30 in the fentanyl group). The primary outcome was met in 58% of the alfentanil group and 50% of the fentanyl group (difference 8%, 95% confidence interval: -17% to 33%). The 30-day mortality rate, first-pass success rate, and incidences of hypertension, hypotension, and hypoxia were similar between the groups. There were no significant differences in systolic blood pressure or heart rate between the groups at any of the measured time-points. Conclusion: Alfentanil and fentanyl produced comparable post-induction hemodynamic changes when used as adjuncts to ketamine in ED RSI. Future studies could consider comparing different dosages of these opioids.
KW - Alfentanil
KW - Fentanyl
KW - Hypertension
KW - Hypotension
KW - Ketamine
KW - Rapid sequence induction and intubation
UR - http://www.scopus.com/inward/record.url?scp=85199340294&partnerID=8YFLogxK
U2 - 10.1016/j.ajem.2024.07.027
DO - 10.1016/j.ajem.2024.07.027
M3 - Article
C2 - 39059038
AN - SCOPUS:85199340294
SN - 0735-6757
VL - 84
SP - 25
EP - 32
JO - American Journal of Emergency Medicine
JF - American Journal of Emergency Medicine
ER -