Behavior of concrete filled steel tubular (CFST) triple-limb laced columns subjected to ISO 834 standard fire

Z. Q. Cui, L. H. Han, T. Y. Song

    Research output: Chapter in Book / Conference PaperConference Paperpeer-review

    Abstract

    ![CDATA[Finite element analysis (FEA) model is established to study the behavior of concrete filled steel tubular (CFST) triple-limb laced columns subjected to ISO 834 standard fire. Some key mechanics characteristics on the fire performance of CFST triple-limb laced columns, including temperature distribution, failure mode, fire resistance, axial deformation and load distributions, are discussed based on the established FEA model. Finally, parametric analysis is performed to investigate the influence of various parameters, including slenderness ratio, load ratio, load eccentricity ratio, steel and concrete strength, on the fire resistance of CFST triple-limb laced columns, and the major influencing parameters are identified.]]
    Original languageEnglish
    Title of host publicationProceedings of the 2013 World Congress on Advances in Structural Engineering and Mechanics (ASEM13): 8-12 September 2013, Jeju, Korea
    PublisherTechno-Press
    Pages2608-2618
    Number of pages11
    ISBN (Print)9788989693376
    Publication statusPublished - 2013
    EventWorld Congress on Advances in Structural Engineering and Mechanics -
    Duration: 8 Sept 2013 → …

    Conference

    ConferenceWorld Congress on Advances in Structural Engineering and Mechanics
    Period8/09/13 → …

    Fingerprint

    Dive into the research topics of 'Behavior of concrete filled steel tubular (CFST) triple-limb laced columns subjected to ISO 834 standard fire'. Together they form a unique fingerprint.

    Cite this