Behaviour of short and slender concrete-filled stainless steel tubular columns

Brian Uy, Zhong Tao, Lin-Hai Han

    Research output: Contribution to journalArticle

    389 Citations (Scopus)

    Abstract

    In this paper, a series of tests were carried out on short and slender concrete-filled stainless steel tubular columns to explore their performance under axial compression or combined actions of axial force and bending moment. Empty short steel hollow sections were also tested for comparison. The test results showed that the performance of the composite columns was quite good and have the potential to be used extensively as structural members. Comparisons of the test results were also made with several existing design methods for conventional concrete-filled carbon steel tubular columns as presented in Australian standard AS 5100 (2004), American code AISC (2005), Chinese code DBJ/T 13-51-2010 (2010), and Eurocode 4 (2004), which indicates that all the codes are somewhat conservative in predicting the load-carrying capacities of both short and slender columns.
    Original languageEnglish
    Pages (from-to)360-378
    Number of pages19
    JournalJournal of Constructional Steel Research
    Volume67
    Issue number3
    DOIs
    Publication statusPublished - 2011

    Keywords

    • axial loads
    • bending
    • columns
    • concrete-filled tubes
    • stainless steel
    • strength

    Fingerprint

    Dive into the research topics of 'Behaviour of short and slender concrete-filled stainless steel tubular columns'. Together they form a unique fingerprint.

    Cite this