Comparative analysis of extended aeration and Fenton process in landfill leachate treatment

Kashif Mahmud, Md. Delwar Hossain, Shahriar Shams, Md. Al-Amin

Research output: Contribution to journalArticlepeer-review

Abstract

This research is undertaken to investigate various operating conditions for minimising sludge disposal and maximising chemical oxygen demand from leachate. With conventional extended aeration process the optimum removal of COD and colour were 36% and 24% respectively. In Fenton process, for optimum pH of 5 and optimum H2O2/Fe2+ molar ratio of 1.3, the dosages of H2O2 and Fe2+ were found 1000 mg/l and 1250 mg/l, respectively. Under these conditions, the achievements for optimum COD and colour removal were 80% and 97%, respectively, while a combined treatment process of aeration followed by Fenton process resulted into higher COD and colour removals.
Original languageEnglish
Pages (from-to)233-252
Number of pages20
JournalInternational Journal of Environmental Engineering
Volume4
Issue number45385
DOIs
Publication statusPublished - 2012

Keywords

  • aeration
  • Fenton’s reagent
  • sanitary landfills
  • leaching
  • oxidation

Fingerprint

Dive into the research topics of 'Comparative analysis of extended aeration and Fenton process in landfill leachate treatment'. Together they form a unique fingerprint.