TY - JOUR
T1 - Comparison of surgical outcomes using Gyrus PKSâ„¢ vs LigaSureâ„¢ in total laparoscopic hysterectomy : a randomised controlled trial
AU - Wong, Clare
AU - Goh, Amy
AU - Merkur, Harry
PY - 2020
Y1 - 2020
N2 - Background: Advanced vessel sealing devices are widely used in laparoscopic surgery. However, there remains a lack of adequately powered trials comparing laparoscopic advanced vessel sealing devices in the clinical setting, especially in gynaecology. Aims: This single-blinded randomised controlled trial aims to compare the surgical outcomes of total laparoscopic hysterectomy (TLH) using either the Gyrus PKS™ LYONS dissecting forceps or the LigaSure™ Maryland jaw vessel sealer/divider. Materials and Methods: Women who required TLHs for benign indications were randomised to having their surgeries performed using either Gyrus PKS™ or LigaSure™. Time to haemostasis (from initial skin incision to detachment of the uterus with secured haemostasis) was the primary outcome; a 20% difference in time was considered clinically significant. Secondary outcomes measured were intra-operative blood loss, complications, conversions, post-operative analgesia use, and length of stay. This study was registered with the Australia New Zealand Clinical Trials Registry ACTRN12615000639516. Results: Sixty-four women were included in the study" 33 and 31 in the Gyrus PKS™ and LigaSure™ arms, respectively. TLHs performed by LigaSure™ had statistically significantly shorter time to haemostasis compared to Gyrus PKS™ by 10.6 min (95% CI 1.3-2.0, P = 0.03). There were no differences in any of the other secondary outcomes measured. Conclusions: This trial suggests there is no difference between using either device. TLHs performed using LigaSure™ have statistically significantly shorter time to haemostasis than those using Gyrus PKS™; however, the difference is not considered clinically significant as it was only 14.2%. No other differences in surgical outcomes were detected.
AB - Background: Advanced vessel sealing devices are widely used in laparoscopic surgery. However, there remains a lack of adequately powered trials comparing laparoscopic advanced vessel sealing devices in the clinical setting, especially in gynaecology. Aims: This single-blinded randomised controlled trial aims to compare the surgical outcomes of total laparoscopic hysterectomy (TLH) using either the Gyrus PKS™ LYONS dissecting forceps or the LigaSure™ Maryland jaw vessel sealer/divider. Materials and Methods: Women who required TLHs for benign indications were randomised to having their surgeries performed using either Gyrus PKS™ or LigaSure™. Time to haemostasis (from initial skin incision to detachment of the uterus with secured haemostasis) was the primary outcome; a 20% difference in time was considered clinically significant. Secondary outcomes measured were intra-operative blood loss, complications, conversions, post-operative analgesia use, and length of stay. This study was registered with the Australia New Zealand Clinical Trials Registry ACTRN12615000639516. Results: Sixty-four women were included in the study" 33 and 31 in the Gyrus PKS™ and LigaSure™ arms, respectively. TLHs performed by LigaSure™ had statistically significantly shorter time to haemostasis compared to Gyrus PKS™ by 10.6 min (95% CI 1.3-2.0, P = 0.03). There were no differences in any of the other secondary outcomes measured. Conclusions: This trial suggests there is no difference between using either device. TLHs performed using LigaSure™ have statistically significantly shorter time to haemostasis than those using Gyrus PKS™; however, the difference is not considered clinically significant as it was only 14.2%. No other differences in surgical outcomes were detected.
KW - hysterectomy
KW - laparoscopic surgery
UR - https://hdl.handle.net/1959.7/uws:58581
U2 - 10.1111/ajo.13217
DO - 10.1111/ajo.13217
M3 - Article
SN - 0004-8666
VL - 60
SP - 790
EP - 796
JO - Australian and New Zealand Journal of Obstetrics and Gynaecology
JF - Australian and New Zealand Journal of Obstetrics and Gynaecology
IS - 5
ER -