TY - JOUR
T1 - Corneal epithelial thinning profile induced by long-term wear of hydrogel lenses
AU - Pérez, Javier González
AU - Méijome, Jose Manuel González
AU - Jalbert, Isabelle
AU - Sweeney, Deborah F.
AU - Erickson, Paul
PY - 2003
Y1 - 2003
N2 - Purpose. To characterize the epithelial thickness profile and study the effects of long-term wear of hydrogel lenses on this profile. Methods. A cross-sectional study was designed. Epithelial thickness was evaluated in 15 subjects who had worn one of two types of low oxygen transmissibility (Dk) hydrogel contact lenses for an average of 10 years (range, 7-16) and compared with a group of 18 control subjects who had never wom contact lenses. Epithelial thickness was measured at the center and at four mid-peripheral and four peripheral locations in the vertical and horizontal meridians of the cornea using a modified optical pachymeter. Results. Lens wearers had significantly thinner epithelium than controls [analysis of variance (ANOVA), p < 0.001] in the central (41 ± 7 μm versus 48 ± 5 μm), mid-peripheral (41 ± 7 μm versus 48 ± 7 μm), and peripheral (42 ± 9 μm versus 48 ± 6 μm) cornea. The extent of this difference ranged from 8.7% to 18.4% of the total epithelial thickness, was not associated with the duration of wear (ANOVA, p = 0.87, power = 0.05), and was significantly greater for the lower Dk contact lens type (ANOVA, p < 0.001). Topographical position did not have a significant effect on epithelial thickness (ANOVA, p > 0.13, power > 0.22). Conclusion. This study establishes that the epithelial thinning associated with hydrogel lens wear is topographically uniform. It also confirms that this effect is inversely related to lens oxygen transmissibility but does not appear to increase with longer duration of wear.
AB - Purpose. To characterize the epithelial thickness profile and study the effects of long-term wear of hydrogel lenses on this profile. Methods. A cross-sectional study was designed. Epithelial thickness was evaluated in 15 subjects who had worn one of two types of low oxygen transmissibility (Dk) hydrogel contact lenses for an average of 10 years (range, 7-16) and compared with a group of 18 control subjects who had never wom contact lenses. Epithelial thickness was measured at the center and at four mid-peripheral and four peripheral locations in the vertical and horizontal meridians of the cornea using a modified optical pachymeter. Results. Lens wearers had significantly thinner epithelium than controls [analysis of variance (ANOVA), p < 0.001] in the central (41 ± 7 μm versus 48 ± 5 μm), mid-peripheral (41 ± 7 μm versus 48 ± 7 μm), and peripheral (42 ± 9 μm versus 48 ± 6 μm) cornea. The extent of this difference ranged from 8.7% to 18.4% of the total epithelial thickness, was not associated with the duration of wear (ANOVA, p = 0.87, power = 0.05), and was significantly greater for the lower Dk contact lens type (ANOVA, p < 0.001). Topographical position did not have a significant effect on epithelial thickness (ANOVA, p > 0.13, power > 0.22). Conclusion. This study establishes that the epithelial thinning associated with hydrogel lens wear is topographically uniform. It also confirms that this effect is inversely related to lens oxygen transmissibility but does not appear to increase with longer duration of wear.
KW - Epithelial thickness
KW - Hypoxia
KW - Long-term contact lens wear
KW - Low Dk soft contact lenses
KW - Modified optical pachymetry
UR - http://www.scopus.com/inward/record.url?scp=0037986535&partnerID=8YFLogxK
U2 - 10.1097/00003226-200305000-00005
DO - 10.1097/00003226-200305000-00005
M3 - Article
C2 - 12792471
AN - SCOPUS:0037986535
SN - 0277-3740
VL - 22
SP - 304
EP - 307
JO - Cornea
JF - Cornea
IS - 4
ER -