T1 - Development of a high-performance liquid chromatography method for the simultaneous quantitation of glutathione and related thiols
AU - Steele, Megan L.
AU - Ooi, Lezanne
AU - Münch, Gerald
PY - 2012
Y1 - 2012
N2 - The development of drugs with the ability to increase the level of the antioxidant glutathione and related metabolites has become an important research area for many age-related diseases. Here we describe a high-performance liquid chromatography (HPLC) method that uses the thiol-specific, fluorogenic reagent 4-fluoro-7-aminosulfonylbenzofurazan (ABD-F) for the simultaneous determination of total glutathione (GSH), cysteine (Cys), cysteinylglycine (CysGly), and homocysteine (Hcys) in cell culture medium. ABD-F-labeled thiols were separated using an isocratic mobile phase consisting of 14% methanol and 86% 0.1 M acetate buffer at pH 4.0. The method was validated for linearity, accuracy, and intra- and interday precision, and the lower and upper limits of quantitation (LLOQ and ULOQ, respectively) were determined using a Dionex RF-2000 detector set to medium sensitivity. In addition, the suitability of N-acetylcysteine (NAC) as an internal standard was evaluated by external and internal standard calibration methods. Although both calibration methods showed acceptable linearity (correlation coefficients > 0.99) and intra- and interday precision (relative standard deviations = 10.2 and 6.6%, respectively), the external standard calibration method performed better in terms of accuracy (recovery = 93.7-125%) and also had lower LLOQ values for all analytes (Cys = 6.3 μM, CysGly = 0.8 μM, Hcys = 0.8 μM, and GSH = 1.6 μM).
AB - The development of drugs with the ability to increase the level of the antioxidant glutathione and related metabolites has become an important research area for many age-related diseases. Here we describe a high-performance liquid chromatography (HPLC) method that uses the thiol-specific, fluorogenic reagent 4-fluoro-7-aminosulfonylbenzofurazan (ABD-F) for the simultaneous determination of total glutathione (GSH), cysteine (Cys), cysteinylglycine (CysGly), and homocysteine (Hcys) in cell culture medium. ABD-F-labeled thiols were separated using an isocratic mobile phase consisting of 14% methanol and 86% 0.1 M acetate buffer at pH 4.0. The method was validated for linearity, accuracy, and intra- and interday precision, and the lower and upper limits of quantitation (LLOQ and ULOQ, respectively) were determined using a Dionex RF-2000 detector set to medium sensitivity. In addition, the suitability of N-acetylcysteine (NAC) as an internal standard was evaluated by external and internal standard calibration methods. Although both calibration methods showed acceptable linearity (correlation coefficients > 0.99) and intra- and interday precision (relative standard deviations = 10.2 and 6.6%, respectively), the external standard calibration method performed better in terms of accuracy (recovery = 93.7-125%) and also had lower LLOQ values for all analytes (Cys = 6.3 μM, CysGly = 0.8 μM, Hcys = 0.8 μM, and GSH = 1.6 μM).
KW - cysteine
KW - glutathione
KW - high performance liquid chromatography
KW - homocysteine
KW - thiols
UR - http://handle.uws.edu.au:8081/1959.7/518306
U2 - 10.1016/j.ab.2012.06.023
DO - 10.1016/j.ab.2012.06.023
M3 - Article
SN - 0003-2697
VL - 429
SP - 45
EP - 52
JO - Analytical Biochemistry
JF - Analytical Biochemistry
IS - 1
ER -