Dust and noise levels in a teaching padiatry laboratory

Sue Reed, Sue Cusbert, Melanie Reed, Verona Du Toit

    Research output: Chapter in Book / Conference PaperConference Paperpeer-review

    Abstract

    The use of Podiatry services is increasing and the exposure to dust and noise in Podiatry facilities has not been well documented in the literature. Concern for exposure to dust and noise has been raised due to the amount of particles seen when grinding and sanding custom moulded shoe inserts. Shoe inserts are made from a range of materials including polypropylene, polyurethane foams, ethylene/acetate copolymers, vinyl acetate and aluminina trihydrate. Monitoring for PM2.5, PM10 and noise was undertaken in a teaching podiatry laboratory on two days to ascertain if they were at a level hazardous to health. In addition the ventilation system was assessed to determine if the capture velocities were sufficient to determine if the current ventilation system is sufficient to control the potential hazards. Because the laboratory is used by a variety of students during the day, static monitoring was undertaken in preference to personal sampling so that a broad range of exposures could be determined. The results of the dust monitoring shows that the levels of PM2.5 and PM10 were within levels considered adequate from a public health viewpoint although peaks did occur during the clean-up of the laboratory. Noise monitoring highlighted that although the average levels were acceptable there is concern that a number of machines have noise levels exceeding 80 dBA. The ventilation system was assessed from a qualitative (smoke tubes) and quantitative (velocity measurements) viewpoint, and because of the action of the spinning wheels and belt it was determined that they were not adequate
    Original languageEnglish
    Title of host publicationMeeting Global Challenges in Occupational Hygiene : proceedings of 30th Annual Conference & Exhibition of the Australian Institute of Occupational Hygienists Inc, 1-5 December, 2012, Adelaide, South Australia
    PublisherAustralian Institute of Occupational Hygienists
    Pages154-164
    Number of pages11
    ISBN (Print)9780980301045
    Publication statusPublished - 2012
    EventAnnual Conference & Exhibition of the Australian Institute of Occupational Hygienists Inc -
    Duration: 1 Dec 2012 → …

    Conference

    ConferenceAnnual Conference & Exhibition of the Australian Institute of Occupational Hygienists Inc
    Period1/12/12 → …

    Keywords

    • ventalation
    • noise
    • dust
    • podiatry

    Fingerprint

    Dive into the research topics of 'Dust and noise levels in a teaching padiatry laboratory'. Together they form a unique fingerprint.

    Cite this