Dynamic response of structures equipped with Tuned Liquid Column Dampers

Research output: Contribution to journalConference articlepeer-review

5 Citations (Scopus)

Abstract

An exploratory study is made of the possible application of Tuned Liquid Column Dampers (TLCD) as an energy dissipating device to reduce the response of tall buildings and other structures subjected to seismic loads. It is found that TLCD systems are capable of reducing the structure response with a relatively small mass and can achieve the same response reduction levels as those by traditional Tuned Mass Damper (TMD) systems with only half the mass. TLCD system offers several advantages including simplicity and easy tuning and retuning to natural period of the structure.

Original languageEnglish
Pages (from-to)138-143
Number of pages6
JournalNational Conference Publication - Institution of Engineers, Australia
Issue number90 pt 9
Publication statusPublished - 1990
Externally publishedYes
EventAustralian Vibration and Noise Conference 1990 - Melbourne, Aust
Duration: 18 Sept 199020 Sept 1990