TY - JOUR
T1 - Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault earthquakes having forward directivity
AU - Mortezaei, A.
AU - Ronagh, H. R.
AU - Kheyroddin, A.
AU - Ghodrati Amiri, G.
PY - 2011
Y1 - 2011
N2 - Near-fault ground motions with long-period pulses have been identified as being critical in the design of structures. These motions, which have caused severe damage in recent disastrous earthquakes, are characterized by a short-duration impulsive motion that transmits large amounts of energy into the structures at the beginning of the earthquake. In nearly all of the past near-fault earthquakes, significant higher mode contributions have been evident, resulting in the migration of dynamic demands (i.e., drifts) from the lower to the upper stories. Due to this, the static nonlinear pushover analysis (PA) (which utilizes a load pattern proportional to the shape of the fundamental mode of vibration) may not produce accurate results when used in the analysis of structures subjected to near-fault ground motions. The objective of this paper was to improve the accuracy of the pushover method in these situations by introducing a new load pattern into the common pushover procedure. Several PAs are performed for six existing reinforced concrete buildings that possess a variety of natural periods. Then, a comparison is made between the PA results (with four new load patterns) and those of FEMA-356 with reference to nonlinear dynamic time-history analyses. The comparison shows that, generally, the proposed pushover method yields better results than all FEMA-356 PA procedures for all investigated response quantities, and is a closer match to the nonlinear time-history responses. In general, the method is able to reproduce the essential response features providing a reasonable measure of the likely contribution of higher modes in all phases of the response.
AB - Near-fault ground motions with long-period pulses have been identified as being critical in the design of structures. These motions, which have caused severe damage in recent disastrous earthquakes, are characterized by a short-duration impulsive motion that transmits large amounts of energy into the structures at the beginning of the earthquake. In nearly all of the past near-fault earthquakes, significant higher mode contributions have been evident, resulting in the migration of dynamic demands (i.e., drifts) from the lower to the upper stories. Due to this, the static nonlinear pushover analysis (PA) (which utilizes a load pattern proportional to the shape of the fundamental mode of vibration) may not produce accurate results when used in the analysis of structures subjected to near-fault ground motions. The objective of this paper was to improve the accuracy of the pushover method in these situations by introducing a new load pattern into the common pushover procedure. Several PAs are performed for six existing reinforced concrete buildings that possess a variety of natural periods. Then, a comparison is made between the PA results (with four new load patterns) and those of FEMA-356 with reference to nonlinear dynamic time-history analyses. The comparison shows that, generally, the proposed pushover method yields better results than all FEMA-356 PA procedures for all investigated response quantities, and is a closer match to the nonlinear time-history responses. In general, the method is able to reproduce the essential response features providing a reasonable measure of the likely contribution of higher modes in all phases of the response.
KW - earthquake resistant design
KW - pushover analysis
KW - reinforced concrete construction
UR - http://handle.uws.edu.au:8081/1959.7/uws:32441
U2 - 10.1002/tal.553
DO - 10.1002/tal.553
M3 - Article
SN - 1541-7794
VL - 20
SP - 679
EP - 699
JO - The Structural Design of Tall and Special Buildings
JF - The Structural Design of Tall and Special Buildings
IS - 6
ER -