    The effects of Gac oil extraction conditions including microwave power, microwave time, steaming time and hydraulic pressure on extraction efficiency (EE), and β-carotene and lycopene contents were studied. It was found that the EE, and β-carotene and lycopene contents could be enhanced by suitable extraction conditions. Microwave drying was found to be better than air drying for pretreatment. Moisture content after drying and steaming between 8% and 11% (wt/wt) were best for pressing. Results showed that the most suitable conditions for Gac oil extraction from 900 g samples were microwave power of 630 W, microwave time of 65 min, steaming time of 20 min and hydraulic pressure of 170 kg/cm 2. Under these conditions, the highest EE of 93% was achieved while Gac oil contained the highest content of β-carotene and lycopene at 140 and 414 mg/100 mL, respectively.
    Original languageEnglish
    Pages (from-to)486-491
    Number of pages6
    JournalJournal of Food Engineering
    Volume117
    Issue number4
    DOIs
    Publication statusPublished - 2013