Skip to main navigation Skip to search Skip to main content

Energy and carbon savings in data centres through liquid-to-chip cooling with differential temperature control

  • Queensland University of Technology

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)
7 Downloads (Pure)

Abstract

The rapid and large-scale development of data centres to manage computational demand is resulting in potential strain on electrical energy and water utilities globally. New methods for minimising the peak power demand and annual energy of data centres that can be adapted to the different ambient conditions of various geographic locations are urgently needed. This study applies a novel advanced method of energy savings by differential temperature control via I.T. kW load measurement, to the conversion of data centres from conventional air-to-chip (ATC) cooling, to new liquid-to-chip (LTC) cooling. The novel method potentially assists elimination of energy-intensive chillers in favour of free cooling, reduces peak power demand and annual energy consumption for temperate to tropical ambient conditions. A new energy model was developed in Design Builder™ and EnergyPlus™ and was validated by onsite measurements at a state-of-the-art data centre in Melbourne, Australia and utilised to predict and optimize the improvement in energy efficiency by controlling differential temperature. The results indicate that converting from ATC cooling to LTC cooling could reduce the total peak power demand by 6%∼14% and reduce the annual energy consumption, carbon emissions and power usage efficiency by 4%∼13%. Application of the advanced control method to increase differential temperature from 5 °C to 10 °C for LTC systems, predicted reduction of the PUE from a range of 1.22∼1.25 to 1.18, potentially contributing an 18∼28% reduction in central plant energy.

Original languageEnglish
Article number100269
Number of pages19
JournalAdvances in Applied Energy
Volume22
DOIs
Publication statusPublished - Jun 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Data centre energy
  • Differential temperature
  • Free-cooling economisation optimisation
  • Liquid-to-chip
  • Power usage effectiveness

Fingerprint

Dive into the research topics of 'Energy and carbon savings in data centres through liquid-to-chip cooling with differential temperature control'. Together they form a unique fingerprint.

Cite this