Evaluation of an immunoassay (EMIT) for mycophenolic acid in plasma from renal transplant recipients compared with a high-performance liquid chromatography assay

Joanne L. Beal, Christopher E. Jones, Paul J. Taylor, Susan E. Tett

Research output: Contribution to journalArticlepeer-review

83 Citations (Scopus)

Abstract

Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used Solid phase extraction and a C 18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (± standard deviation [SD]) bias (EMIT-HPLC) was 1 88 ± 0 86 m/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.

Original languageEnglish
Pages (from-to)685-690
Number of pages6
JournalTherapeutic Drug Monitoring
Volume20
Issue number6
DOIs
Publication statusPublished - Dec 1998
Externally publishedYes

Keywords

  • High-performance liquid chromatography Renal transplant
  • Immunoassay
  • Immunosuppressant
  • Mycophenolic acid

Fingerprint

Dive into the research topics of 'Evaluation of an immunoassay (EMIT) for mycophenolic acid in plasma from renal transplant recipients compared with a high-performance liquid chromatography assay'. Together they form a unique fingerprint.

Cite this