How accurate is inpatient blood pressure measurement?

  • Alexandra Gallagher
  • , Brendan Smyth
  • , Sergey Alexeev
  • , George Mangos
  • , Aletta E. Schutte
  • , James E. Sharman
  • , Meg J. Jardine
  • , Mark A. Brown
  • , Inpatient Blood Pressure Measurement Expert Panel
  • , Angela Makris
  • , et al.
  • The University of Sydney
  • St. George Hospital
  • University of New South Wales
  • The George Institute for Global Health
  • University of Tasmania
  • Concord Repatriation General Hospital
  • Western Sydney University

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Accuracy of blood pressure (BP) measurement depends on quality technique, yet there are no existing guidelines for accurate measurement of inpatient BP. We assessed the performance of BP measurements in a major teaching hospital by comparison with consensus criteria. METHODS: Routine BP measurement methods were observed across 3 noncritical care wards (aged care, acute surgical, and hematology) at St George Hospital, Sydney, over a 3-week period. Aspects of BP measurement were compared for concordance with an ideal BP measurement technique, consisting of 10 consensus criteria, as determined by an expert panel. RESULTS: A total of 278 BP measurements were observed in 153 patients. Concordance with the consensus criteria was high for device calibration (92%), uncrossed legs (82%), using the correct cuff size (77%), and back support (75%). Concordance was moderate for the criteria of correctly positioned cuff on a bare arm (both 65%), and poor for the remaining criteria (seated position [26%], no talking [23%], cuff at heart height [15%], and taking at least 2 measurements [7%]). No observed measurement met all 10 of the consensus criteria for BP measurement quality. CONCLUSIONS: Our findings indicate considerable discordance between routine BP measurement and optimal technique (as determined by an expert panel) in an Australian hospital setting. The lowest concordance was observed for the 3 highest-ranked consensus criteria for accurate BP measurement. This variability may result in inaccurate and biased readings. Standardized, hospital-specific BP measurement guidelines and training are needed to improve BP measurement accuracy.

Original languageEnglish
Article numbere26355
Pages (from-to)1679-1688
Number of pages10
JournalHypertension
Volume83
Issue number6
DOIs
Publication statusPublished - Jun 2026
Externally publishedYes

Keywords

  • blood pressure
  • data accuracy
  • humans
  • inpatients
  • quality improvement

Fingerprint

Dive into the research topics of 'How accurate is inpatient blood pressure measurement?'. Together they form a unique fingerprint.

Cite this