T1 - Influence of central corneal thickness on measured intraocular pressure differentials
T2 - Nidek RKT-7700, Topcon CT-80 NCTs and Goldmann Tonometer
AU - Ogbuehi, Kelechi C.
AU - Mucke, Sven
AU - Osuagwu, Uchechukwu L.
PY - 2012/11
Y1 - 2012/11
N2 - Purpose; We sought to compare the intraocular pressure (IOP) measured by RKT-7700 and CT-80 noncontact tonometers (NCTs) with that measured by Goldmann applanation tonometry (GAT). We also examined the influence of central corneal thickness (CCT) on the agreement between both NCTs and GAT in a sub-population of healthy, young normals. Methods: Triplicate IOP and CCT measurements were obtained twice from one randomized eye of 49 subjects (28 males and 21 females) aged 22.2 ± 1.3 (mean ± S.D.) years. Goldmann tonometry was performed subsequent to assessment with the RKT-7700 and CT-80, to negate the 'ocular massage effect', followed by ultrasound pachymetry. The results from each method were compared and assessed for repeatability and between-observer reproducibility. Analysis was performed to determine the correlation between the differences in IOP measurements and corneal thicknesses. Results: The mean differences (±S.D.) in sessions 1 and 2 respectively between RKT-7700 and GAT (2.6 ± 2.0 and 2.7 ± 1.4 mmHg), between CT-80 and GAT (2.8 ± 2.0 and 3.2 ± 1.3 mmHg) were statistically significant (p < 0.0001). The repeatability coefficients in sessions 1 and 2 respectively were; ±1.2 and ±1.0 mmHg (GAT), ±1.3 and ±1.6 mmHg (CT-80), ±2.3 and ±1.7 mmHg (RKT-7700) and inter-observer reproducibility was; ±1.9 (RKT-7700), ±2.3 (GAT) and ±2.6 mmHg (CT-80). Between the corneal thickness and the differences in GAT-measured and NCT-measured IOPs, there was a significant negative correlation and a trend for a larger difference in thicker corneas. Conclusion: Neither the RKT-7700 nor the CT-80 can be used interchangeably with the Goldmann tonometer, although all three tonometers give repeatable measurements of IOP, in this sub-population. IOP differences between GAT and the NCTs significantly correlated with CCT, with the possibility of even greater differences in thicker corneas.
AB - Purpose; We sought to compare the intraocular pressure (IOP) measured by RKT-7700 and CT-80 noncontact tonometers (NCTs) with that measured by Goldmann applanation tonometry (GAT). We also examined the influence of central corneal thickness (CCT) on the agreement between both NCTs and GAT in a sub-population of healthy, young normals. Methods: Triplicate IOP and CCT measurements were obtained twice from one randomized eye of 49 subjects (28 males and 21 females) aged 22.2 ± 1.3 (mean ± S.D.) years. Goldmann tonometry was performed subsequent to assessment with the RKT-7700 and CT-80, to negate the 'ocular massage effect', followed by ultrasound pachymetry. The results from each method were compared and assessed for repeatability and between-observer reproducibility. Analysis was performed to determine the correlation between the differences in IOP measurements and corneal thicknesses. Results: The mean differences (±S.D.) in sessions 1 and 2 respectively between RKT-7700 and GAT (2.6 ± 2.0 and 2.7 ± 1.4 mmHg), between CT-80 and GAT (2.8 ± 2.0 and 3.2 ± 1.3 mmHg) were statistically significant (p < 0.0001). The repeatability coefficients in sessions 1 and 2 respectively were; ±1.2 and ±1.0 mmHg (GAT), ±1.3 and ±1.6 mmHg (CT-80), ±2.3 and ±1.7 mmHg (RKT-7700) and inter-observer reproducibility was; ±1.9 (RKT-7700), ±2.3 (GAT) and ±2.6 mmHg (CT-80). Between the corneal thickness and the differences in GAT-measured and NCT-measured IOPs, there was a significant negative correlation and a trend for a larger difference in thicker corneas. Conclusion: Neither the RKT-7700 nor the CT-80 can be used interchangeably with the Goldmann tonometer, although all three tonometers give repeatable measurements of IOP, in this sub-population. IOP differences between GAT and the NCTs significantly correlated with CCT, with the possibility of even greater differences in thicker corneas.
KW - Cornea thickness
KW - Intraocular pressure
KW - Noncontact tonometer
KW - Repeatability
KW - Ultrasound pachymetry
UR - http://www.scopus.com/inward/record.url?scp=84867433919&partnerID=8YFLogxK
U2 - 10.1111/j.1475-1313.2012.00945.x
DO - 10.1111/j.1475-1313.2012.00945.x
M3 - Article
C2 - 23009324
AN - SCOPUS:84867433919
SN - 0275-5408
VL - 32
SP - 547
EP - 555
JO - Ophthalmic & Physiological Optics
JF - Ophthalmic & Physiological Optics
IS - 6
ER -