Abstract
![CDATA[This work is in the response of concrete-metal bond problem in structures used in infrastructure engineering such as concrete-filled steel pipes and columns. In this paper the capabilities of near-field microwave waveguide sensors for the purpose of measurement and monitoring of gap between concrete and metal surfaces is demonstrated. It was shown that a microwave dielectric-loaded waveguide sensor provides higher sensitivity to the gap than a conventional open-ended waveguide sensor. The performances of the dielectric-loaded waveguide sensor are studied and optimised.]]
Original language | English |
---|---|
Title of host publication | Proceedings of 2012 IEEE International Instrumentation and Measurement Technology Conference, 13-16 May 2012, Graz, Austria |
Publisher | IEEE |
Pages | 2440-2443 |
Number of pages | 4 |
ISBN (Print) | 9781457717734 |
DOIs | |
Publication status | Published - 2012 |
Event | IEEE International Instrumentation and Measurement Technology Conference - Duration: 6 May 2013 → … |
Conference
Conference | IEEE International Instrumentation and Measurement Technology Conference |
---|---|
Period | 6/05/13 → … |
Keywords
- concrete-filled tubes
- gaps
- microwaves
- tubes, steel