Measurement of pulmonary flow reserve and pulmonary index of microcirculatory resistance for detection of pulmonary microvascular obstruction

Rahn Ilsar, Chirapan Chawantanpipat, Kim H. Chan, Timothy A. Dobbins, Richard Waugh, Annemarie Hennessy, David S. Celermajer, Martin K. C. Ng

    Research output: Contribution to journalArticle

    11 Citations (Scopus)

    Abstract

    Background. The pulmonary microcirculation is the chief regulatory site for resistance in the pulmonary circuit. Despite pulmonary microvascular dysfunction being implicated in the pathogenesis of several pulmonary vascular conditions, there are currently no techniques for the specific assessment of pulmonary microvascular integrity in humans. Peak hyperemic flow assessment using thermodilution-derived mean transit-time (Tmn) facilitate accurate coronary microcirculatory evaluation, but remain unvalidated in the lung circulation. Using a high primate model, we aimed to explore the use of Tmn as a surrogate of pulmonary blood flow for the purpose of measuring the novel indices Pulmonary Flow Reserve [PFR = (maximum hyperemic)/(basal flow)] and Pulmonary Index of Microcirculatory Resistance [PIMR = (maximum hyperemic distal pulmonary artery pressure)×(maximum hyperemic Tmn)]. Ultimately, we aimed to investigate the effect of progressive pulmonary microvascular obstruction on PFR and PIMR. Methods and Results. Temperature- and pressure-sensor guidewires (TPSG) were placed in segmental pulmonary arteries (SPA) of 13 baboons and intravascular temperature measured. Tmn and hemodynamics were recorded at rest and following intra-SPA administration of the vasodilator agents adenosine (10–400 µg/kg/min) and papaverine (3–24 mg). Temperature did not vary with intra-SPA sensor position (0.010±0.009 v 0.010±0.009°C; distal v proximal; p = 0.1), supporting Tmn use in lung for the purpose of hemodynamic indices derivation. Adenosine (to 200 µg/kg/min) & papaverine (to 24 mg) induced dose-dependent flow augmentations (40±7% & 35±13% Tmn reductions v baseline, respectively; p< 0.0001). PFR and PIMR were then calculated before and after progressive administration of ceramic microspheres into the SPA. Cumulative microsphere doses progressively reduced PFR (1.41±0.06, 1.26±0.19, 1.17±0.07 & 1.01±0.03; for 0, 104, 105 & 106 microspheres; p = 0.009) and increased PIMR (5.7±0.6, 6.3±1.0, 6.8±0.6 & 7.6±0.6 mmHg.sec; p = 0.0048). Conclusions. Thermodilution-derived mean transit time can be accurately and reproducibly measured in the pulmonary circulation using TPSG. Mean transit time-derived PFR and PIMR can be assessed using a TPSG and adenosine or papaverine as hyperemic agents. These novel indices detect progressive pulmonary microvascular obstruction and thus have with a potential role for pulmonary microcirculatory assessment in humans.
    Original languageEnglish
    Number of pages9
    JournalPLoS One
    Volume5
    Issue number5
    DOIs
    Publication statusPublished - 2010

    Open Access - Access Right Statement

    Copyright: 2010 Ilsar et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

    Keywords

    • blood flow
    • blood-vessels
    • diseases, obstructive
    • lungs
    • pulmonary circulation

    Fingerprint

    Dive into the research topics of 'Measurement of pulmonary flow reserve and pulmonary index of microcirculatory resistance for detection of pulmonary microvascular obstruction'. Together they form a unique fingerprint.