Skip to main navigation Skip to search Skip to main content

Nasal high-flow therapy for newborn infants in special care nurseries

  • Brett J. Manley
  • , Gaston R. B. Arnolda
  • , Ian M. R. Wright
  • , Louise S. Owen
  • , Jann P. Foster
  • , Li Huang
  • , Calum T. Roberts
  • , Tracey L. Clark
  • , Wei-Qi Fan
  • , Alice Y. W. Fang
  • , Isaac R. Marshall
  • , Rosalynn J. Pszczola
  • , Peter G. Davis
  • , Adam G. Buckmaster

Research output: Contribution to journal › Article › peer-review

78 Citations (Scopus)

Abstract

BACKGROUND Nasal high-flow therapy is an alternative to nasal continuous positive airway pressure (CPAP) as a means of respiratory support for newborn infants. The efficacy of high-flow therapy in nontertiary special care nurseries is unknown. METHODS We performed a multicenter, randomized, noninferiority trial involving newborn infants (<24 hours of age; gestational age, ≥31 weeks) in special care nurseries in Australia. Newborn infants with respiratory distress and a birth weight of at least 1200 g were assigned to treatment with either high-flow therapy or CPAP. The primary outcome was treatment failure within 72 hours after randomization. Infants in whom high-flow therapy failed could receive CPAP. Noninferiority was determined by calculating the absolute difference in the risk of the primary outcome, with a noninferiority margin of 10 percentage points. RESULTS A total of 754 infants (mean gestational age, 36.9 weeks, and mean birth weight, 2909 g) were included in the primary intention-to-treat analysis. Treatment failure occurred in 78 of 381 infants (20.5%) in the high-flow group and in 38 of 373 infants (10.2%) in the CPAP group (risk difference, 10.3 percentage points; 95% confidence interval [CI], 5.2 to 15.4). In a secondary per-protocol analysis, treatment failure occurred in 49 of 339 infants (14.5%) in the high-flow group and in 27 of 338 infants (8.0%) in the CPAP group (risk difference, 6.5 percentage points; 95% CI, 1.7 to 11.2). The incidences of mechanical ventilation, transfer to a tertiary neonatal intensive care unit, and adverse events did not differ significantly between the groups. CONCLUSIONS Nasal high-flow therapy was not shown to be noninferior to CPAP and resulted in a significantly higher incidence of treatment failure than CPAP when used in nontertiary special care nurseries as early respiratory support for newborn infants with respiratory distress.
Original languageEnglish
Pages (from-to)2031-2040
Number of pages10
JournalNew England Journal of Medicine
Volume380
Issue number21
DOIs
Publication statusPublished - 2019

Keywords

  • airways
  • newborn infants
  • nurseries
  • respiration

Fingerprint

Dive into the research topics of 'Nasal high-flow therapy for newborn infants in special care nurseries'. Together they form a unique fingerprint.

Cite this