TY - JOUR
T1 - Numerical modelling of concrete-filled steel box columns incorporating high strength materials
AU - Thai, Huu-Tai
AU - Uy, Brian
AU - Khan, Mahbub
AU - Tao, Zhong
AU - Mashiri, Fidelis
PY - 2014
Y1 - 2014
N2 - In this paper, an accurate finite element model which accounts for the effects of initial local imperfections and residual stresses is developed for the nonlinear analysis of high strength steel box columns infilled with high strength concrete. The inelastic behaviour of the steel box and the concrete core is modelled using an elastic-plastic model with linear hardening and a concrete damaged plasticity model, respectively. In addition, an extensive numerical analysis based on a wide range of width-to-thickness ratios, yield stresses of steel tubes and compressive strengths of concrete core was also carried out to propose a new empirical equation for estimating the confining pressure on the concrete. The predictions of ultimate strengths, behaviour and failure modes are compared with experimental results to verify the accuracy of the present model. Parameter studies indicate that both the Eurocode EC4 and Australian Standard AS 5100 approaches can be safely extended to predict the ultimate strength of concrete-filled steel columns with high strength materials.
AB - In this paper, an accurate finite element model which accounts for the effects of initial local imperfections and residual stresses is developed for the nonlinear analysis of high strength steel box columns infilled with high strength concrete. The inelastic behaviour of the steel box and the concrete core is modelled using an elastic-plastic model with linear hardening and a concrete damaged plasticity model, respectively. In addition, an extensive numerical analysis based on a wide range of width-to-thickness ratios, yield stresses of steel tubes and compressive strengths of concrete core was also carried out to propose a new empirical equation for estimating the confining pressure on the concrete. The predictions of ultimate strengths, behaviour and failure modes are compared with experimental results to verify the accuracy of the present model. Parameter studies indicate that both the Eurocode EC4 and Australian Standard AS 5100 approaches can be safely extended to predict the ultimate strength of concrete-filled steel columns with high strength materials.
UR - http://handle.uws.edu.au:8081/1959.7/547574
U2 - 10.1016/j.jcsr.2014.07.014
DO - 10.1016/j.jcsr.2014.07.014
M3 - Article
SN - 0143-974X
VL - 102
SP - 256
EP - 265
JO - Journal of Constructional Steel Research
JF - Journal of Constructional Steel Research
ER -