Point of care ultrasound screening, performed by midwives, outperforms standard selective screening for hip dysplasia. A diagnostic accuracy study

  • Hans Christen Husum
  • , Rikke Damkjær Maimburg
  • , Michel Bach Hellfritzsch
  • , Bjarne Møller-Madsen
  • , Mads Henriksen
  • , Natallia Lapitskaya
  • , Søren Kold
  • , Ole Rahbek

Research output: Contribution to journalArticlepeer-review

Abstract

Background and purpose: To investigate the accuracy of pubo-femoral distance (PFD) ultrasound (US) performed by midwives as a referral criterion for diagnostic Graf hip US, compared to standard screening for developmental dysplasia of the hip (DDH) in newborns. Methods: PFD US screening was performed along standard screening for DDH in a prospective cohort. The accuracy of PFD US was compared to the standard referral criteria for diagnostic hip US in terms of sensitivity, specificity and positive predictive value in detecting abnormal hips, as well as proportion of abnormal hips found and referral rates. Results: We included 2735 newborns of which 488 received a diagnostic hip US. Mean age at diagnostic US was 35.5 days (±12.8). 317 newborns (11.7 %) were referred by Danish standard screening criteria and 206 newborns (7.6 %) were referred by the PFD criterion. Sensitivities/specificities for detecting ≥Graf type IIc hips were: 50 %/68 % for risk factors, 30 %/94 % for clinical examination, 60 %/62 % for risk factors + clinical examination, and 80 %/89 % for PFD US using a cut-off of 6.2 mm. Difference in sensitivity between PFD and standard screening criteria did not reach statistical significance, but specificity and PPV did. The number of detected ≥ Graf type IIc hips were 6 and 9 for standard screening and PFD screening respectively. Interpretation: Early point-of-care PFD US screening for DDH has significantly higher accuracy in classifying abnormal hips, when compared to standard screening. PFD US increases the detection rate of dysplastic hips (≥ Graf IIc) by 60 % while reducing referral rates.

Original languageEnglish
Article number104459
JournalMidwifery
Volume147
DOIs
Publication statusPublished - Aug 2025
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Mass screening
  • Midwives
  • Pediatric radiology
  • Ultrasound

Fingerprint

Dive into the research topics of 'Point of care ultrasound screening, performed by midwives, outperforms standard selective screening for hip dysplasia. A diagnostic accuracy study'. Together they form a unique fingerprint.

Cite this