Skip to main navigation Skip to search Skip to main content

Quantifying the early recoil of post-angioplasty lesions in the native arterio-venous fistula

  • Umer Khan
  • , Nathan Turner
  • , Lukas Kairaitis
  • , David Burgess
  • , Tracie Barber
  • , Luke Baker
  • , Jan Swinnen
  • , Shannon Thomas
  • Prince of Wales Hospital
  • National University Hospital
  • Western Renal Service
  • University of New South Wales
  • Westmead Hospital
  • The University of Sydney

Research output: Contribution to journal › Article › peer-review

Abstract

Background: Despite technically successful angioplasty of native arteriovenous fistula (AVF) stenoses, early luminal loss may occur before routine post-angiography surveillance. While elastic recoil is recognized intra-procedurally, delayed reduction in luminal diameter from early post-angioplasty recoil (EPR) remains poorly characterized. Methods: We performed a retrospective secondary analysis of a multicenter randomized controlled trial comparing drug-eluting balloons (DEB) with sham balloons for recurrent AVF stenoses in 102 patients. Minimum luminal diameter on completion angiography (D0) was compared with the first post-angioplasty ultrasound performed within 14 days (D1). EPR was defined as >30% reduction in luminal diameter between D0 and D1. Baseline clinical, vascular access, and procedural variables were analyzed to identify predictors of EPR. Re-intervention rates and luminal changes at 6 months were assessed. Results: Of 129 trial participants, 102 had complete angiographic and ultrasound datasets. EPR occurred in 42 patients (41%), with a mean diameter reduction of 43.7%. AVFs demonstrating EPR were significantly older than those without recoil (mean age 3.71 vs 2.33 years; p = 0.022). Patient age, access location, prior interventions, and stent use were not associated with EPR. Mean diameter reduction was 43.7% in the EPR group versus 11.5% in the non-EPR group (p < 0.001). Overall 6-month re-intervention rates were similar between groups; however, subgroup analysis demonstrated that EPR accounted for approximately 45% of total luminal loss in 27/102 patients requiring repeat intervention. DEB use did not influence EPR but was associated with reduced late restenosis. Conclusions: Early post-angioplasty luminal loss detected on ultrasound is common following AVF angioplasty and occurs more frequently in older fistulas. EPR contributes substantially to subsequent restenosis and may represent an under-recognized mechanism of early treatment failure. Selective early ultrasound surveillance may help identify patients at increased risk of early luminal compromise.

Original languageEnglish
Number of pages9
JournalJournal of Vascular Access
DOIs
Publication statusE-pub ahead of print (In Press) - 2026
Externally publishedYes

Keywords

  • AV fistula
  • dialysis
  • dialysis access
  • interventional radiology
  • techniques and procedures
  • ultrasonography—Doppler evaluation

Fingerprint

Dive into the research topics of 'Quantifying the early recoil of post-angioplasty lesions in the native arterio-venous fistula'. Together they form a unique fingerprint.

Cite this