TY - JOUR
T1 - Reliability of surface electromyography for the gluteus medius muscle during gait in people with and without chronic nonspecific low back pain
AU - Sadler, S.
AU - Spink, M.
AU - Chuter, V.
PY - 2020
Y1 - 2020
N2 - The purpose of this study was to determine the intratester reliability of surface electromyography (EMG) assessment of the gluteus medius muscle in healthy people and people with chronic nonspecific low back pain (CNLBP) during barefoot walking. Gluteus medius muscle activity was measured twice in 40 people without and 30 people with CNLBP approximately 7 days apart. Walking gluteus medius muscle activity was normalised to maximal voluntary isometric contractions during side-lying hip abduction with manual resistance. Good intratester reliability (ICC > 0.75) was found for mean, peak, and peak to peak amplitude for healthy people. Only mean amplitude demonstrated good intratester reliability in those with CNLBP. Peak amplitude and peak to peak amplitude of the gluteus medius muscle of those with CNLBP, and the time of peak amplitude in both groups, demonstrated moderate reliability (ICC ranged from 0.50 to 0.58). Moderate to large standard error of measurement and minimal detectable change values were reported for outcome measurements. These results suggest that potentially large levels of random error can occur between sessions. Future research can build on this study for those with pathology and attempt to establish change values for EMG that are clinically meaningful.
AB - The purpose of this study was to determine the intratester reliability of surface electromyography (EMG) assessment of the gluteus medius muscle in healthy people and people with chronic nonspecific low back pain (CNLBP) during barefoot walking. Gluteus medius muscle activity was measured twice in 40 people without and 30 people with CNLBP approximately 7 days apart. Walking gluteus medius muscle activity was normalised to maximal voluntary isometric contractions during side-lying hip abduction with manual resistance. Good intratester reliability (ICC > 0.75) was found for mean, peak, and peak to peak amplitude for healthy people. Only mean amplitude demonstrated good intratester reliability in those with CNLBP. Peak amplitude and peak to peak amplitude of the gluteus medius muscle of those with CNLBP, and the time of peak amplitude in both groups, demonstrated moderate reliability (ICC ranged from 0.50 to 0.58). Moderate to large standard error of measurement and minimal detectable change values were reported for outcome measurements. These results suggest that potentially large levels of random error can occur between sessions. Future research can build on this study for those with pathology and attempt to establish change values for EMG that are clinically meaningful.
UR - http://hdl.handle.net/1959.7/uws:66709
U2 - 10.1016/j.jelekin.2020.102457
DO - 10.1016/j.jelekin.2020.102457
M3 - Article
SN - 1050-6411
VL - 54
JO - Journal of Electromyography and Kinesiology
JF - Journal of Electromyography and Kinesiology
M1 - 102457
ER -