TY - JOUR
T1 - Simple and robust determination of monosaccharides in plant fibers in complex mixtures by capillary electrophoresis and high performance liquid chromatography
AU - Oliver, James D.
AU - Gaborieau, Marianne
AU - Hilder, Emily F.
AU - Castignolles, Patrice
PY - 2013
Y1 - 2013
N2 - Carbohydrates partially liberated by acid hydrolysis of plant fiber can be separated by hydrophilic interaction liquid chromatography (HILIC), ligand-exchange liquid chromatography or other forms of LC with ion-exchange columns. However, the robust hydrogen-exchange columns show co-elution of galactose, xylose and mannose. Free solution capillary electrophoresis (CE) can be used without derivatization at pH 12.6 and was found to provide a higher resolution of galactose and xylose than common LC with no sample pre-treatment required, other than dilution, within 26 min. CE was able to provide resolution higher than 0.79 for all separated carbohydrates, and the RSDs of determined concentrations lower than 10% for concentrations above 1.3 g L−1. A quantitative comparison between CE and HPLC revealed that up to 22% more carbohydrates are quantified with CE. Direct UV detection in CE of mono- and disaccharides is unexpectedly possible at 270 nm. NMR analysis shows that alkaline degradation is too slow to explain this detection. This CE detection sensitivity is increased by the electric field and our CE and NMR analyses are consistent with a photo-oxidation process.
AB - Carbohydrates partially liberated by acid hydrolysis of plant fiber can be separated by hydrophilic interaction liquid chromatography (HILIC), ligand-exchange liquid chromatography or other forms of LC with ion-exchange columns. However, the robust hydrogen-exchange columns show co-elution of galactose, xylose and mannose. Free solution capillary electrophoresis (CE) can be used without derivatization at pH 12.6 and was found to provide a higher resolution of galactose and xylose than common LC with no sample pre-treatment required, other than dilution, within 26 min. CE was able to provide resolution higher than 0.79 for all separated carbohydrates, and the RSDs of determined concentrations lower than 10% for concentrations above 1.3 g L−1. A quantitative comparison between CE and HPLC revealed that up to 22% more carbohydrates are quantified with CE. Direct UV detection in CE of mono- and disaccharides is unexpectedly possible at 270 nm. NMR analysis shows that alkaline degradation is too slow to explain this detection. This CE detection sensitivity is increased by the electric field and our CE and NMR analyses are consistent with a photo-oxidation process.
KW - capillary electrophoresis
KW - ion, exchange resins
KW - monosaccharides
KW - plant fibers
UR - http://handle.uws.edu.au:8081/1959.7/527329
U2 - 10.1016/j.chroma.2013.03.041
DO - 10.1016/j.chroma.2013.03.041
M3 - Article
SN - 0021-9673
VL - 1291
SP - 179
EP - 186
JO - Journal of Chromatography A
JF - Journal of Chromatography A
ER -