Abstract
![CDATA[In this paper, the safety factors in AS 5100 (Standards Australia 2004) for short concrete-filled steel tubular (CFST) columns are calibrated based on the statistical method proposed by Johnson & Huang (1997). This method is applied to an extensive database developed by Tao et al. (2008) which has 929 CFST stub column test results covering a wide range of input parameters. A summary of the calibration procedure and the calibrated safety factors are provided. The reasons for the calibration results are discussed to provide useful insight and supporting information for a possible revision of AS 5100.]]
| Original language | English |
|---|---|
| Title of host publication | From Materials to Structures: Advancement through Innovation: Proceedings of the 22nd Australasian Conference on the Mechanics of Structures and Materials: ACMSM 22: Sydney, Australia, 11-14 December 2012 |
| Publisher | CRC Press |
| Pages | 953-958 |
| Number of pages | 6 |
| ISBN (Print) | 9780415633185 |
| Publication status | Published - 2012 |
| Event | Australasian Conference on the Mechanics of Structures and Materials - Duration: 11 Dec 2012 → … |
Conference
| Conference | Australasian Conference on the Mechanics of Structures and Materials |
|---|---|
| Period | 11/12/12 → … |
Keywords
- columns
- concrete-filled tubes
- steel, structural
- calibration
- standards
Fingerprint
Dive into the research topics of 'Statistical safety factor calibration of short concrete-filled steel tubular columns'. Together they form a unique fingerprint.Cite this