The impact of imaging modality (CT vs MRI) and patient position (supine vs prone) on tangential whole breast radiation therapy planning

Kylie Dundas, Elise M. Pogson, Vikneswary Batumalai, Geoff P. Delaney, Miriam M. Boxer, Mei Ling Yap, Verity Ahern, Christine Chan, Steven David, Marion Dimigen, Jennifer A. Harvey, Eng-Siew Koh, Karen Lim, George Papadatos, Elizabeth Lazarus, Joseph Descellar, Peter Metcalfe, Lois Holloway

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

Purpose: The purpose of this study was to evaluate the impact of magnetic resonance imaging (MRI) versus computed tomography (CT)-derived planning target volumes (PTVs), in both supine and prone positions, for whole breast (WB) radiation therapy. Methods and materials: Four WB radiation therapy plans were generated for 28 patients in which PTVs were generated based on CT or MRI data alone in both supine and prone positions. A 6-MV tangential intensity modulated radiation therapy technique was used, with plans designated as ideal, acceptable, or noncompliant. Dose metrics for PTVs and organs at risk were compared to analyze any differences based on imaging modality (CT vs MRI) or patient position (supine vs prone). Results: With respect to imaging modality 2/11 whole breast planning target volume (WB_PTV) dose metrics (percentage of PTV receiving 90% and 110% of prescribed dose) displayed statistically significant differences; however, these differences did not alter the average plan compliance rank. With respect to patient positioning, the odds of having an ideal plan versus a noncompliant plan were higher for the supine position compared with the prone position (P = .026). The minimum distance between the seroma cavity planning target volume (SC_PTV) and the chest wall was increased with prone positioning (P < .001, supine and prone values 1.1 mm and 8.7 mm, respectively). Heart volume was greater in the supine position (P = .005). Heart doses were lower in the supine position than prone (P less than .01, mean doses 3.4 +/- 1.55 Gy vs 4.4 ± 1.13 Gy for supine vs prone, respectively). Mean lung doses met ideal dose constraints in both positions, but were best spared in the prone position. The contralateral breast maximum dose to 1cc (D1cc) showed significantly lower doses in the supine position (P < .001, 4.64 Gy vs 9.51 Gy). Conclusions: Planning with PTVs generated from MRI data showed no clinically significant differences from planning with PTVs generated from CT with respect to PTV and doses to organs at risk. Prone positioning within this study reduced mean lung dose and whole heart volumes but increased mean heart and contralateral breast doses compared with supine.
Original languageEnglish
Pages (from-to)E87-E97
Number of pages24
JournalPractical Radiation Oncology
Volume8
Issue number3
DOIs
Publication statusPublished - 2018

Keywords

  • breast
  • magnetic resonance imaging
  • radiotherapy
  • tomography