TY - JOUR
T1 - The reliability of running performance in a 5 km time trial on a non-motorized treadmill
AU - Stevens, C. J.
AU - Hacene, J.
AU - Sculley, D. V.
AU - Taylor, L.
AU - Callister, R.
AU - Dascombe, B.
PY - 2015
Y1 - 2015
N2 - The purpose of the study was to establish the reliability of performance and physiological responses during a self-paced 5 km running time trial on a non-motorized treadmill. 17 male runners (age: 32±13 years, height: 177±7 cm, body mass: 71±9 kg, sum of 7 skinfolds: 55±21 mm) performed familiarization then 2 separate maximal 5 km running time trials on a non-motorized treadmill. Physiological responses measured included heart rate, oxygen uptake, expired air volume, blood lactate concentration, tissue saturation index and integrated electromyography. Running time (1 522±163 s vs. 1 519±162 s for trials 1 and 2, respectively) demonstrated a low CV of 1.2% and high ICC of 0.99. All physiological variables had CVs of less than 4% and ICCs of >0.92, with the exception of blood lactate concentration (7.0±2 mmol·L-1 vs. 6.5±1.5 mmol·L-1 for trials 1 and 2, respectively; CV: 12%, ICC: 0.83) and the electromyography measures (CV: 8-27%, ICC: 0.71-0.91). The data demonstrate that performance time in a 5 km running time trial on a non-motorized treadmill is a highly reliable test. Most physiological responses measured across the 5 km run also demonstrated good reliability.
AB - The purpose of the study was to establish the reliability of performance and physiological responses during a self-paced 5 km running time trial on a non-motorized treadmill. 17 male runners (age: 32±13 years, height: 177±7 cm, body mass: 71±9 kg, sum of 7 skinfolds: 55±21 mm) performed familiarization then 2 separate maximal 5 km running time trials on a non-motorized treadmill. Physiological responses measured included heart rate, oxygen uptake, expired air volume, blood lactate concentration, tissue saturation index and integrated electromyography. Running time (1 522±163 s vs. 1 519±162 s for trials 1 and 2, respectively) demonstrated a low CV of 1.2% and high ICC of 0.99. All physiological variables had CVs of less than 4% and ICCs of >0.92, with the exception of blood lactate concentration (7.0±2 mmol·L-1 vs. 6.5±1.5 mmol·L-1 for trials 1 and 2, respectively; CV: 12%, ICC: 0.83) and the electromyography measures (CV: 8-27%, ICC: 0.71-0.91). The data demonstrate that performance time in a 5 km running time trial on a non-motorized treadmill is a highly reliable test. Most physiological responses measured across the 5 km run also demonstrated good reliability.
UR - https://hdl.handle.net/1959.7/uws:71674
U2 - 10.1055/s-0034-1398680
DO - 10.1055/s-0034-1398680
M3 - Article
SN - 0172-4622
VL - 36
SP - 705
EP - 709
JO - International Journal of Sports Medicine
JF - International Journal of Sports Medicine
IS - 9
ER -