T1 - True unipolar ECG machine for Wilson Central Terminal measurements
AU - Gargiulo, Gaetano D.
PY - 2015
Y1 - 2015
N2 - Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of "Wilson Central Terminal" in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis) associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography) has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wtlson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wtlson Central Terminal when limb electrodes are placed close to the torso.
AB - Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of "Wilson Central Terminal" in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis) associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography) has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wtlson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wtlson Central Terminal when limb electrodes are placed close to the torso.
KW - ECG
KW - cardiology
KW - diagnostics
KW - electrocardiography
UR - http://handle.uws.edu.au:8081/1959.7/uws:30462
UR - http://www.hindawi.com/journals/bmri/aa/586397/
U2 - 10.1155/2738
DO - 10.1155/2738
M3 - Article
SN - 2314-6141
SN - 2314-6133
VL - 2015
JO - BioMed Research International
JF - BioMed Research International
M1 - 586397
ER -