Abstract
Hydrogen sulfide (H2S) generated in sewer systems leads to serious problems in sewer when H2S is emitted to air and reacts with concrete surfaces or causes obnoxious odour and potential toxicity. Numerous methods have been employed to control corrosion by minimising production and emission H2S or/and treating corrosion at the concrete surface. Each method has its own limitations and the reported efficiency and cost vary from researcher to researcher. This could be mostly due to the poor access which prevented better understanding of the fundamentals. The partial flow sewer system is also poorly understood due to difficulty in simulating the sewer system in the laboratory. The partial flow system is exposed to the atmosphere and experiences a high flow velocity. Yet, hydrogen sulfide is formed in the system within 8-24 h of retention time.During my master research, a combination of three traditionally used methods –pH adjustment to 8.0, ferrous chloride and oxygen dosing - was found to be more efficient in reducing liquid and gaseous phase H2S concentration. The discrepancy between actual H2S gas phase measurements and the theoretical gas phase concentrations was also identified. Dosed ferrous was a small amount, i.e. approximately 10% of the stoichiometric requirement to precipitate sulfide and thus likely catalytic mechanism was indicated. Some experiments were carried out in Milli-Q to confirm the catalytic effect. However, the exact mechanism was not known or the importance of the pH adjustment was not known. As adjustment of pH is complicated in real sewer system, it is important to understand if this could be prevented. The PhD project was undertaken to fill this knowledge gap and to explore any other efficient methods.
The dosing of chemicals (ferrous, chlorine) or aeration may have altered the microbial community. Bacterial communities from the inflow and outflow of laboratory-scale sewer systems (after implementing corrosion control methods and before implementing) were analyzed. However, there is no significant difference in the bacterial community between the air-dosed wastewater- and combine air + ferrous wastewater. However, Clostridia parentage has been reduced in both air only and air + chlorine dose rectors (Chorine + air dosed experiment). It does not recover even in the downstream reactor.
| Date of Thesis submission | 2021 |
|---|---|
| Original language | English |
| Awarding Institution |
|
| Supervisor | Sathaa Arumugam Sathasivan (Supervisor) |
Cite this
- Standard