Skip to main navigation Skip to search Skip to main content

Evaluation of portable GC-MS for the in-field identification of samples at clandestine laboratories

  • Paige Walker

Western Sydney University thesis: Master's thesis

Abstract

Clandestine laboratories are illegal laboratories in which the manufacture of illicit substances, or precursors of those substances, occurs. The investigation of these types of crime scenes involves the identification of unknown samples. Identification of unknown samples in the field at clandestine laboratories is commonly performed using pH testing, followed by portable Fourier Transform Infrared spectroscopy (FTIR) and/or portable Raman spectroscopy. Whilst this approach is reliable for pure materials or mixtures of only two components, the results can only be considered presumptive for mixtures containing multiple components, and components present at low concentrations may be missed all together. Colorimetric presumptive tests can also be used as these tests are sensitive and able to detect target compounds at low levels even in mixtures, although they are prone to false positives. As such, only limited intelligence is obtained in the field during the investigation of a clandestine laboratory, especially when mixtures of chemicals are encountered, and collected samples typically require further laboratory testing. The aim of this project was to evaluate whether a person-portable GC-MS can detect and identify illicit substances and other components commonly present in clandestine laboratory samples (such as precursors, intermediate products and cutting agents) in the field, including those that are in mixtures. The second aim of this study was to determine whether a common laboratory-based sampling protocol to analyse clandestine laboratory samples is suitable for use in the field. To address these aims, mixed reference standards of commonly encountered substances within Australian clandestine laboratories were analysed to determine the identification capabilities of the portable GC-MS. Forty authentic clandestine laboratory samples were analysed and the results produced by the portable GC-MS were compared with laboratory-based GC-MS results. Results from these analyses demonstrated that the TRIDION T-9 could successfully detect the high concentration compounds within samples, although struggled with the detection and identification of low concentration compounds and minor constituents. The comparison of the portable GC-MS results with laboratory-based FTIR results demonstrated that, in some cases, portable GC-MS analyses could provide additional intelligence that was not able to be obtained from FTIR analyses. Although further research is recommended, in particular by evaluating the portable GC-MS under field conditions, this study determined that person-portable GC-MS can detect and identify illicit substances and other components commonly present in clandestine laboratory samples, and would likely be valuable in producing additional intelligence to onsite FTIR analyses if included within the in-field investigation of clandestine laboratories.
Date of Thesis submission2022
Original languageEnglish
Awarding Institution
  • Western Sydney University
SupervisorVal Spikmans (Supervisor), Brenden Riley (Supervisor), Chris Lennard (Supervisor) & Robert Ebeyan (Supervisor)

Cite this

'